Power Cable

Bus Drop Cable- UL Listed Thermoplastic Jacketed (PVC)- 600V (14)

Applications

  • As branches from busways per NEC.
  • Connection of stationary equipment to facilitate relocation of equipment.Features
  • Used in dry location.
  • One uninsulated ground conductor per interstice.
  • Resistant to oils, lubricants, water, acids, alkalies, ozone and abrasion.
  • EPR-CPE Power Cable Type TC with Grounding Conductor- 600V- 90°C Dry - 75°C Wet (14)

    Phase conductors are cabled together with Class B stranded, tinned copper grounding conductor and suitable non-hygroscopic fillers. Cable assembly covered with a suitable tape.

    EPR-HYP Power Cable- 3 Conductor w/ Ground, 4 Conductor w/o Ground Type TC (26)

    UL listed and OSHA acceptable. Recognized for use in Class 1, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts, conduit and aerially where supported by a messenger. Specifically approved for direct burial, wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required. Designed to supply power to motors, or for connections to other power devices.

    Low Smoke, Zero Halogen (LSZH), 600 Volt, 3 and 4 Conductor Cables (29)

    XLPO/LSZH, Low Voltage Power, Unshielded 600V, UL Type TC-LS-ER - Method 4 Color Code

    THHN Power Cable- 3 Conductor With and Without Ground- Type TC 90°C Dry - 75°C Wet - 600V (23)

    THHN/TC cable is approved for tray, raceway, direct burial and aerial installations (when supported by messenger). It is also approved for tray use in Class 1, Division 2, hazardous locations as permitted in NEC Articles 318 and 501. It complies with the appropriate sections of NEC Articles 318, 340, 501 and 725.

    THHN Power Cable- 4 Conductor With and Without Ground- Type TC 90°C Dry - 75°C Wet - 600V (23)

    THHN/TC cable is approved for tray, raceway, direct burial and aerial installations (when supported by messenger). It is also approved for tray use in Class 1, Division 2, hazardous locations as permitted in NEC Articles 318 and 501. It complies with the appropriate sections of NEC Articles 318, 340, 501 and 725.

    VFD Power Cables (17)

    For Low Voltage Variable Frequency Drive Systems XLPE Insulation PVC Jacket Shielded 600 Volt

    XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V (14)

    As flame-retardant three conductor power cables rated 600 volts, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.

    XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V (13)

    As flame-retardant four conductor power cables rated 600 volts, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.

    XLP-CPE Power Cable Type TC with Grounding Conductor- 600V- 90°C Wet or Dry (24)

    600 Volt - XHHW-2 Insulation, CPE Jacket 90ºC Wet or Dry - Type TC - UL