Aluminum Cable
ACSR Aluminum Conductor- Steel Reinforced (18)
Application
- Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
All-Aluminum Cable and Tie Wire- Overhead Distribution AAC (33)For use in overhead transmission and distribution systems, and as bus connections in substations and switchyards. Solid conductors used for mechanical and grounding applications.
Applications
Aluminum Service Entrance Type SE, Style R 600V- 90°C WET OR DRY (12)Above ground service entrance, panel feeder in multiple dwellings, range and dryer and other branch circuits.
Maximum operating temperature of phase conductors not to exceed 90°C in wet or dry locations.
600 Volts, approved for use as specified by the NEC®.
Applications
Aluminum URD Cable- 600 Volt- Quadruplex-90°C For Direct Burial (9)Underground distribution from a supply source to the service entrance equipment of a building.
Maximum operating temperature of 90°C in dry and wet locations.
Direct burial application or in ducts.
600 volts.
Aluminum URD Cable- 600V- Triplex 90°C For Direct Burial (14)Underground distribution from a supply source to the service entrance equipment of a building.
Maximum operating temperature of 90°C in dry and wet locations.
Direct burial application or in ducts.
600 volts.
Applications
Overhead Service Drop Cable- Duplex, Triplex and Quadruplex (14)Primarily used for 120-volt overhead service applications such as street lighting, outdoor lighting, and temporary service. To be used at voltages of 600 volts or less at conductor temperatures not to exceed 75° C.for Triplex
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene insulated conductors (on special order).for Quadruplex
Used to supply 3-phase power, usually from a ...
Applications:
for Duplex
XHHW Type MC 600V Aluminum Cable (30)Aluminum MC cable is listed with UL (Standard no. 1479) for "through-penetration" of fire rated floors or walls.
Aluminum MC cable meets the requirements of UL 1569, metal clad cables. Rated at 600 Volts, the cable is approved for use in accordance with Article 334 and other applicable portions of the NEC.
Applications