Medium Voltage Power Cable
Application
Applications
Three Conductor, EPR Insulation/Copper Tape Shield With Overall PVC Jacket. Shielded, 15kV, UL Type MV-105, 133%/100% Ins. Levels, 220 Mil Insulation
Three Conductor, EPR Insulation, PVC Jacket, 2400 Volt, Unshielded, MV 105
Three Conductor, EPR Insulation/Copper Tape Shield With Overall PVC Jacket, Shielded 5kV And 8kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mil Insulation
Application:
As medium voltage MV-90 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installation. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts 100% insulation level, at conductor temperatures not exceeding 90°C for normal, 130°C for emergency overload and 250°C for short circuit conditions. Suitable for installation in conduit, tray, trough, ducts, aerial and direct burial applications.
As medium voltage MV-105 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts 100% insulation level, at conductor temperatures not exceeding 105°C for normal, 140°C for emergency overload and 250°C for short-circuit conditions.Cables may be installed in conduit, duct or aerially when properly supported by a messenger.
As medium voltage MV-105 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts 100% insulation level, at conductor temperatures not exceeding 105°C for normal, 140°C for emergency overload and 250°C for short-circuit conditions.Cables may be installed in conduit, duct or aerially when properly supported by a messenger.
Where NEC jurisdiction applies; as 2,400- volt non-shielded power cable, Type MV-90, for use at conductor temperatures not exceeding 90°C in wet or dry locations. Cables meet requirements of Article 310-6 of the NEC.
Cable is suitable for use in dry or wet locations at conductor temperatures not exceeding 90°C normal use, 130°C emergency overload, 250°C short circuit. All sizes may be installed in conduit, duct, or directly buried.
Medium voltage MV-105 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 5000 volts 133% insulation level or 8000 volts 100% insulation level, at conductor temperatures not exceeding 105°C for normal, 140°C for emergency overload and 250°C for short-circuit conditions. Suitable for installation in conduit, tray, trough, ducts, aerial and direct burial applications.
EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded 15kV, UL Type MV-105, 133% ins. Level, 220 MilsDimensions and weights are nominal; subject to industry tolerances.
EPR/Copper Tape Shield with Overall LSZH Jacket Medium-Voltage Power, Shielded 15kV, UL Type MV-105, 133% Ins. Level, 220 Mils, Three ConductorDimensions and weights are nominal; subject to industry tolerances.
EPR/Copper Tape Shield with Overall LSZH Jacket, Medium-Voltage Power, Shielded 5kV and 8kV, UL Type MV-105, 133%/100% ins. Levels, 115 Mils, Three ConductorDimensions and weights are nominal; subject to industry tolerances.
EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded 5kV and 8kV, UL Type MV-105, 133%/100% ins. Levels, 115 MilsDimensions and weights are nominal; subject to industry tolerances.
Class B strand, bare annealed copper, insulated with heat and moisture resistant XHHW . The conductors shall be cabled in a left hand lay and a messenger of 30% E.H.S. copperclad steel shall be laid parallel and banded with a rounded edge flat bare copper binding strap.
For use on Single Phase Underground Distribution Systems with solidly grounded neutral, suitable for direct burial or installation in ducts.
For use on Single Phase Underground Distribution Systems with solidly grounded neutral, suitable for direct burial or installation in ducts.
5000 volt shielded power cable, Type MV-90, for general purpose applications in accordance with the NEC at conductor temperatures not exceeding 90°C in wet or dry locations for normal operation, 130°C for emergency overload, and 250°C for short circuit conditions. Suitable for installation in conduit, trough, ducts, aerial and direct burial applications.
As medium voltage MV-90 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts, 100% insulation level, at conductor temperatures not exceeding 90°C for normal, 130°C for emergency overload and 250°C for short-circuit conditions. Suitable for installation in conduit, trough, ducts, aerial and direct burial applications.
Phase identified, (Color coded tape (Black, Red, Blue) applied under the metallic shielding tape) and cabled together with fillers and bare copper ground conductor.
Unshielded: Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant crosslinked polyethylene (type XLP)
Where NEC jurisdiction applies; as 5,000 volt non-shielded power cable, Type MV-90 Dry, for use at conductor temperatures not exceeding 90°C in dry locations. Cables meet requirements of Article 310-6 of the NEC.
Unshielded: Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant crosslinked polyethylene (type XLP).
As medium voltage MV-90 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts, 100% insulation level, at conductor temperatures not exceeding 90°C for normal, 130°C for emergency overload and 250°C for short-circuit conditions. Suitable for installation in conduit, trough, ducts, aerial and direct burial applications.