Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V
For lighting and power applications in accordance with the NEC and for other general purpose wiring applications. Suitable for use in circuits not exceeding 600 volts at conductor temperatures not exceeding 90°C in wet or dry locations. May be installed in raceway, duct, cable tray, direct burial and aerial installations
Item # | Item Name | Size (AWG/MCM) | Strands | Nominal Insulation Thickness (inches) | Nominal Jacket Thickness (inches) | Nominal O.D. (inches) | Current (amps)90°C USE-2RHW-2 RHH | Current (amps)75°C USE-2RHH | Current (amps)90°C USE-2RHW-2 | Nominal Weight(LBS/MFT) | RFQ |
---|---|---|---|---|---|---|---|---|---|---|---|
34003 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 12 | 7 | 0.030 | 0.015 | 0.200 | 30 | 25 | - | 35 | Request a Quote |
34005 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 10 | 7 | 0.030 | 0.015 | 0.220 | 40 | 35 | - | 50 | Request a Quote |
34007 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 8 | 7 | 0.045 | 0.015 | 0.290 | 55 | 50 | - | 80 | Request a Quote |
34008 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 6 | 7 | 0.045 | 0.030 | 0.350 | 75 | 65 | - | 125 | Request a Quote |
34009 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 4 | 7 | 0.045 | 0.030 | 0.390 | 95 | 85 | - | 180 | Request a Quote |
34011 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 2 | 7 | 0.045 | 0.030 | 0.460 | 130 | 115 | - | 270 | Request a Quote |
34012 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 1 | 19 | 0.055 | 0.045 | 0.550 | 150 | 130 | - | 360 | Request a Quote |
34013 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 1/0 | 19 | 0.055 | 0.045 | 0.590 | 170 | 150 | 169 | 435 | Request a Quote |
34014 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 2/0 | 19 | 0.055 | 0.045 | 0.640 | 195 | 175 | 195 | 530 | Request a Quote |
34015 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 3/0 | 19 | 0.055 | 0.045 | 0.690 | 225 | 200 | 228 | 650 | Request a Quote |
34016 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 4/0 | 19 | 0.055 | 0.045 | 0.750 | 260 | 230 | 263 | 805 | Request a Quote |
34017 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 250 | 37 | 0.065 | 0.065 | 0.850 | 290 | 255 | 296 | 980 | Request a Quote |
34019 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 350 | 37 | 0.065 | 0.065 | 0.950 | 350 | 310 | 371 | 1320 | Request a Quote |
34021 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 500 | 37 | 0.065 | 0.065 | 1.080 | 430 | 380 | 455 | 1825 | Request a Quote |
34024 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 750 | 61 | 0.080 | 0.065 | 1.300 | 535 | 475 | 664 | 2690 | Request a Quote |
34026 | Direct Burial Building Wire Type USE-2 (EPR-HYP), 600V | 1000 | 61 | 0.080 | 0.065 | 1.460 | 615 | 545 | 791 | 3520 | Request a Quote |