Request For Quote

Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 2095

Applications

  • Electronic Circuits where RF shielding is required
  • Radio transmitters
  • Sound systems
  • Recording studios
  • Provides good flexibility.
  • Excellent shielding for noise reduction.Features
  • Spiral shield allows ease of ‘pigtail’ soldering
  • Maximum flexibility
  • Item #Item NameSize (AWG/MCM)No. of ConductorsStrandsNominal Insulation Thickness (inches)Nominal Jacket Thickness (inches)Nominal O.D (inches)Nominal Capacitance Conductor to Conductor (pF/ft)Nom Capacitance Bet. Cond 1 and other Conds Connected to Shield (pF/ft)Nominal Weight(LBS/MFT)RFQ
    7602Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 20952227/300.0150.0300.212386827Request a Quote
    7603Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 20952237/300.0150.0300.221376632Request a Quote
    7604Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 20952247/300.0150.0300.237356239Request a Quote
    7612Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 20952027/280.0160.0300.230427631Request a Quote
    7613Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 20952037/280.0160.0300.240427639Request a Quote
    7614Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 20952047/280.0160.0300.259397046Request a Quote
    7622Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209518216/300.0160.0300.252448044Request a Quote
    7623Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209518316/300.0160.0300.264427652Request a Quote
    7624Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209518416/300.0160.0300.286407267Request a Quote
    7632Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209516219/290.0160.0300.285509057Request a Quote
    7633Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209516319/290.0160.0300.299468264Request a Quote
    7642Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209514241/300.0200.0300.317529371Request a Quote
    7643Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209514341/300.0200.0300.334509092Request a Quote
    7652Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209512265/300.0200.0300.3596011094Request a Quote
    7653Multi-Conductor Braid Shield 80°C 300V Type CL2 and CM CSA PCC UL 209512365/300.0200.0300.37955100125Request a Quote