XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
As flame-retardant three conductor power cables rated 600 volts, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.
Item # | Item Name | Size (AWG/MCM) | Strands | Nominal Insulation Thickness (inches) | Nominal Jacket Thickness (inches) | Nominal O.D (inches) | Ground Wire Size AWG | Current at 75° C (Amps) | Current at 90° C (Amps) | Nominal Weight(LBS/MFT) | RFQ |
---|---|---|---|---|---|---|---|---|---|---|---|
13100 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 8 | 7 | 0.045 | 0.060 | 0.660 | 10 | 50 | 55 | 325 | Request a Quote |
13101 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 6 | 7 | 0.045 | 0.060 | 0.740 | 8 | 65 | 75 | 450 | Request a Quote |
13102 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 4 | 7 | 0.045 | 0.080 | 0.880 | 8 | 85 | 95 | 655 | Request a Quote |
13103 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 2 | 7 | 0.045 | 0.080 | 1.000 | 6 | 115 | 130 | 960 | Request a Quote |
13104 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 1 | 19 | 0.055 | 0.080 | 1.130 | 6 | 130 | 150 | 1170 | Request a Quote |
13105 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 1/0 | 19 | 0.055 | 0.080 | 1.220 | 6 | 150 | 170 | 1425 | Request a Quote |
13106 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 2/0 | 19 | 0.055 | 0.080 | 1.310 | 6 | 175 | 195 | 1720 | Request a Quote |
13107 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 3/0 | 19 | 0.055 | 0.080 | 1.420 | 4 | 200 | 225 | 2140 | Request a Quote |
13108 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 4/0 | 19 | 0.055 | 0.080 | 1.550 | 4 | 230 | 260 | 2635 | Request a Quote |
13109 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 250 | 37 | 0.065 | 0.110 | 1.760 | 4 | 255 | 290 | 3180 | Request a Quote |
13110 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 350 | 37 | 0.065 | 0.110 | 1.980 | 3 | 310 | 350 | 4285 | Request a Quote |
13111 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 500 | 37 | 0.065 | 0.110 | 2.260 | 2 | 380 | 430 | 5940 | Request a Quote |
13112 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 750 | 61 | 0.080 | 0.110 | 2.710 | 1 | 475 | 535 | 9010 | Request a Quote |
13113 | XHHW Power Cable- 3 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 1000 | 61 | 0.080 | 0.140 | 3.100 | 1/0 | 545 | 615 | 11700 | Request a Quote |