XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
As flame-retardant four conductor power cables rated 600 volts, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.
Item # | Item Name | Size (AWG/MCM) | Strands | Nominal Insulation Thickness (inches) | Nominal Jacket Thickness (inches) | Nominal O.D (inches) | Ground Wire Size AWG | Current at 90° C- Direct Burial (Amps) | Current at 75° C- Direct Burial (Amps) | Current at 90° C Tray (Amps) | Current at 75° C Tray (Amps) | Nominal Weight(LBS/MFT) | RFQ |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
13120 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 8 | 7 | 0.045 | 0.060 | 0.720 | 12 | 44 | 40 | 55 | 50 | 415 | Request a Quote |
13121 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 6 | 7 | 0.045 | 0.060 | 0.810 | 10 | 60 | 52 | 75 | 65 | 575 | Request a Quote |
13122 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 4 | 7 | 0.045 | 0.080 | 0.960 | 10 | 76 | 68 | 95 | 85 | 840 | Request a Quote |
13123 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 2 | 7 | 0.045 | 0.080 | 1.100 | 9 | 104 | 92 | 130 | 115 | 1200 | Request a Quote |
13124 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 1 | 19 | 0.055 | 0.080 | 1.250 | 9 | 120 | 104 | 150 | 130 | 1545 | Request a Quote |
13125 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 1/0 | 19 | 0.055 | 0.080 | 1.350 | 9 | 104 | 120 | 170 | 150 | 1835 | Request a Quote |
13126 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 2/0 | 19 | 0.055 | 0.080 | 1.450 | 9 | 156 | 140 | 195 | 175 | 2195 | Request a Quote |
13127 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 3/0 | 19 | 0.055 | 0.080 | 1.580 | 7 | 180 | 160 | 225 | 200 | 2800 | Request a Quote |
13128 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 4/0 | 19 | 0.055 | 0.110 | 1.770 | 7 | 208 | 184 | 260 | 230 | 3460 | Request a Quote |
13129 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 250 | 37 | 0.065 | 0.110 | 1.930 | 7 | 232 | 204 | 290 | 255 | 4040 | Request a Quote |
13130 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 350 | 37 | 0.065 | 0.110 | 2.180 | 6 | 280 | 248 | 350 | 310 | 5475 | Request a Quote |
13131 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 500 | 37 | 0.065 | 0.110 | 2.500 | 5 | 344 | 304 | 430 | 380 | 7635 | Request a Quote |
13132 | XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V | 750 | 61 | 0.080 | 0.140 | 3.120 | 4 | 428 | 380 | 535 | 475 | 11400 | Request a Quote |